Citation link: http://dx.doi.org/10.25819/ubsi/10186
Files in This Item:
File Description SizeFormat
IBSync.pdf11.52 MBAdobe PDFThumbnail
View/Open
Dokument Type: Article
metadata.dc.title: IBSync: Intra-body synchronization and implicit contextualization of wearable devices using artificial ECG landmarks
Authors: Wolling, Florian 
Van Laerhoven, Kristof 
Institute: Department Elektrotechnik - Informatik 
Free keywords: Intra-body communication (IBC), Synchronization, Context awareness, Electrocardiography (ECG), Wearable devices
Dewey Decimal Classification: 004 Informatik
GHBS-Clases: TWK
TZI
Issue Date: 2022
Publish Date: 2022
Source: Frontiers in Computer Science ; 4, 915448. - DOI: https://doi.org/10.3389/fcomp.2022.915448
Abstract: 
With a smaller form factor and a larger set of applications, body-worn devices have evolved into a collection of simultaneously deployed hardware units, rather than into a single all-round wearable. The sensor data, logged by such devices across the user's body, contains a wealth of information but is often difficult to synchronize. Especially the application of machine learning techniques, e.g., for activity recognition, suffers from the inaccuracy of the devices' internal clocks. In recent years, intra-body communication emerged as a promising alternative to the traditional wired and wireless communication techniques. Distributed wearable systems will notably benefit from its advantages, such as a superior energy efficiency. However, due to the absence of commercially available platforms, applications using this innovative technique remain rare and underinvestigated. With IBSync, we present a novel concept in which artificial landmark signals are received by body-worn devices on touching, approaching, or passing certain areas, surfaces, or objects with embedded transmitter beacons. The landmark signals enable both the wearables' intentional or incidental synchronization as well as the implicit contextualization using supplementary information about the beacons' situational context. For the detection of the landmarks, we propose to repurpose the on-board ECG sensor front-end available in recent commercial wearable devices. Evaluated on a total of 215 min of recordings from two devices, we demonstrate the concept's feasibility and a promising synchronization error of 0.80±1.79 samples or 6.25±14.00 ms at a device's sampling rate of 128 Hz.
Description: 
Finanziert aus dem Open-Access-Publikationsfonds der Universität Siegen für Zeitschriftenartikel
DOI: http://dx.doi.org/10.25819/ubsi/10186
URN: urn:nbn:de:hbz:467-22758
URI: https://dspace.ub.uni-siegen.de/handle/ubsi/2275
Appears in Collections:Geförderte Open-Access-Publikationen

This item is protected by original copyright

Show full item record

Page view(s)

286
checked on Nov 28, 2024

Download(s)

79
checked on Nov 28, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.